Compact Burner System with Mass Flow Controllers (MFCs) and Mass Flow Meters (MFMs)

  • Cyhoeddwyd gyntaf: 02 Awst 2023
  • Wedi'i addasu ddiwethaf: 02 Awst 2023

Cynnwys

Crynodeb

OCID:
ocds-kuma6s-133710
Cyhoeddwyd gan:
Cardiff University
ID Awudurdod:
AA0258
Dyddiad cyhoeddi:
02 Awst 2023
Dyddiad Cau:
-
Math o hysbysiad:
Hysbysiad Tybiannol
Mae ganddo ddogfennau:
Nac Ydi
Wedi SPD:
Nac Ydi
Mae ganddo gynllun lleihau carbon:
Nac Ydi

Crynodeb

Cardiff University have conducted market testing, with these exercises suggesting there is a limited market for the requirement. In order to confirm this is the case, Cardiff University would like to further test the market by publishing this notice, and to invite suppliers to express their interest in fulfilling this requirement. Please see below the list for Mass Flow Controllers (MFC) and Mass Flow Meters (MFM). They are all essential. Delivery time - by October 2023. 1. •Ammonia liquid MFC - 35 g/s. •P1 inlet pressure: up to 10 bara •P2 outlet pressure: High as possible 2. •Ammonia gaseous MFM - 2500 SLPM. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: 1 bara 3. •Ammonia gaseous MFC - 500 SLPM. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: up to 7 bara (controllable) 4. •Air gaseous MFC - 5000 SLPM. •P1 inlet pressure: up to 10 bara •P2 outlet pressure: 1 - 8 bara (controllable) 5. •Air gaseous MFM - 185 m/s. •P1 inlet pressure: up to 16 bara •P2 outlet pressure: 1 - 5 bara (controllable) 6. •H2 gaseous MFC - 1.5 g/s. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: up to 7 bara (controllable) 7. •(24.9% N2, 75% H2, 0.1% NH3) gaseous MFC - 1.5 g/s. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: up to 7 bara (controllable) 8. •(24.9% N2, 75% H2, 0.1% NH3) gaseous MFM - 6 g/s. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: 1 bara 9. •C3H8 gaseous MFC - 400 SLPM. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: up to 7 bara (controllable) 10. •Water MFC - 15 g/s. •P1 inlet pressure: up to 5 bara •P2 outlet pressure: 1 bara 11. Control system like flowbus/modbus to control all the above instruments from one computer. Cardiff University would welcome contact by prospective suppliers who are able to supply the above list in its entirety. Should you wish to express interest in this requirement, please send an inquiry to the following email address - RoweR4@cardiff.ac.uk.

Testun llawn y rhybydd

HYSBYSIAD TYBIANNOL – CENEDLAETHOL

SUPPLIES

1 Manylion yr Awdurdod

1.1

Enw a Chyfeiriad yr Awdurdod


Cardiff University

Procurement, Procurement Services, McKenzie House, 30-36 Newport Road,

Cardiff

CF24 0DE

UK

Rhys Rowe

+44 2920879648

RoweR4@cardiff.ac.uk

http://www.cardiff.ac.uk/business/why-work-with-us/for-suppliers

1.2

Cyfeiriad ar gyfer cael gwybodaeth bellach


Cardiff University

Procurement, Procurement Services, McKenzie House, 30-36 Newport Road,

Cardiff

CF24 0DE

UK

Rhys Rowe

+44 2920879648

RoweR4@cardiff.ac.uk

http://www.cardiff.ac.uk/business/why-work-with-us/for-suppliers

2 Manylion y Contract

2.1

Teitl

Compact Burner System with Mass Flow Controllers (MFCs) and Mass Flow Meters (MFMs)

2.2

Disgrifiad o'r nwyddau neu'r gwasanaethau sydd eu hangen

Cardiff University have conducted market testing, with these exercises suggesting there is a limited market for the requirement. In order to confirm this is the case, Cardiff University would like to further test the market by publishing this notice, and to invite suppliers to express their interest in fulfilling this requirement.

Please see below the list for Mass Flow Controllers (MFC) and Mass Flow Meters (MFM). They are all essential. Delivery time - by October 2023.

1. •Ammonia liquid MFC - 35 g/s. •P1 inlet pressure: up to 10 bara •P2 outlet pressure: High as possible

2. •Ammonia gaseous MFM - 2500 SLPM. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: 1 bara

3. •Ammonia gaseous MFC - 500 SLPM. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: up to 7 bara (controllable)

4. •Air gaseous MFC - 5000 SLPM. •P1 inlet pressure: up to 10 bara •P2 outlet pressure: 1 - 8 bara (controllable)

5. •Air gaseous MFM - 185 m/s. •P1 inlet pressure: up to 16 bara •P2 outlet pressure: 1 - 5 bara (controllable)

6. •H2 gaseous MFC - 1.5 g/s. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: up to 7 bara (controllable)

7. •(24.9% N2, 75% H2, 0.1% NH3) gaseous MFC - 1.5 g/s. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: up to 7 bara (controllable)

8. •(24.9% N2, 75% H2, 0.1% NH3) gaseous MFM - 6 g/s. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: 1 bara

9. •C3H8 gaseous MFC - 400 SLPM. •P1 inlet pressure: up to 8 bara •P2 outlet pressure: up to 7 bara (controllable)

10. •Water MFC - 15 g/s. •P1 inlet pressure: up to 5 bara •P2 outlet pressure: 1 bara

11. Control system like flowbus/modbus to control all the above instruments from one computer.

Cardiff University would welcome contact by prospective suppliers who are able to supply the above list in its entirety.

Should you wish to express interest in this requirement, please send an inquiry to the following email address - RoweR4@cardiff.ac.uk.

NOTE: To register your interest in this notice and obtain any additional information please visit the Sell2Wales Web Site at https://www.sell2wales.gov.wales/Search/Search_Switch.aspx?ID=133710.

2.3

Cod a Dosbarthiad yr Hysbysiad

38340000 Instruments for measuring quantities
1022 Cardiff and Vale of Glamorgan

3 Gwybodaeth Weinyddol

3.1

Rhif cyfeirnod a roddwyd i'r hysbysiad gan yr awdurdod contractio

N/a

3.2

Dyddiad Dechrau Amcangyfrifedig y Weithdrefn Ddyfarnu

  15 - 08 - 2023

4 Gwybodaeth Arall

4.1

Gwybodaeth Ychwanegol

Cardiff University are looking for expressions of interest for this requirement. Prospective bidders must be able to deliver goods by the end of October 2023. Please express interest in supplying the list of requirements to RoweR4@cardiff.ac.uk.

The deadline for expression of interest for this notice is 17:00 on 15/08/23.

(WA Ref:133710)

4.2

Lawrlwytho Dogfennaeth Ychwanegol

Dd/g

4.3

Dyddiad cyhoeddi'r hysbysiad hwn

  02 - 08 - 2023

Codio

Categorïau nwyddau

ID Teitl Prif gategori
38340000 Offerynnau ar gyfer mesur meintiau Offerynnau mesur

Lleoliadau Dosbarthu

ID Disgrifiad
1022 Caerdydd a Bro Morgannwg

Cyfyngiadau Rhanbarthol ar y Rhybuddion

Mae’r prynwr wedi cyfyngu’r rhybuddion ar gyfer yr hysbysiad hwn i gyflenwyr yn y rhanbarthau canlynol.

ID Disgrifiad
Nid oes cyfyngiadau ar y rhybuddion ar gyfer yr hysbysiad hwn.

Ynglŷn â'r prynwr

Prif gyswllt:
RoweR4@cardiff.ac.uk
Cyswllt gweinyddol:
RoweR4@cardiff.ac.uk
Cyswllt technegol:
N/a
Cyswllt arall:
N/a

Gwybodaeth bellach

Dyddiad Manylion
Nid oes unrhyw wybodaeth bellach wedi'i lanlwytho.

0800 222 9004

Mae'r llinellau ar agor rhwng 8:30am a 5pm o ddydd Llun i ddydd Gwener.

Rydym yn croesawu galwadau'n Gymraeg.

We welcome calls in Welsh.