Air Quality Sensors

  • Cyhoeddwyd gyntaf: 13 Rhagfyr 2023
  • Wedi'i addasu ddiwethaf: 13 Rhagfyr 2023

Nid yw'r prynwr yn defnyddio'r wefan hon i weinyddu'r hysbysiad.

I gofnodi eich diddordeb neu gael gwybodaeth neu ddogfennau ychwanegol, darllenwch y cyfarwyddiadau yn Nhestun Llawn yr Hysbysiad. (NODER: Nid oes angen ymateb i Hysbysiadau Dyfarnu Contractau a Hysbysiadau Gwybodaeth Ymlaen Llaw fel arfer)

Cynnwys

Crynodeb

OCID:
ocds-h6vhtk-0424ee
Cyhoeddwyd gan:
West Midlands Combined Authority
ID Awudurdod:
AA51973
Dyddiad cyhoeddi:
13 Rhagfyr 2023
Dyddiad Cau:
-
Math o hysbysiad:
Hysbysiad Gwybodaeth Ymlaen Llaw (PIN)
Mae ganddo ddogfennau:
Nac Ydi
Wedi SPD:
Nac Ydi
Mae ganddo gynllun lleihau carbon:
AMH

Crynodeb

The WMCA requires an air quality sensor supplier to deliver the following:

Sensors - Minimum of 60 sensors to ensure spatial coverage across the 7 constituent local authorities. At a minimum, sensors must monitor PM2.5 at MCERT compliance standard, and it is preferable sensors can be reliably powered without the use of mains power. Sensors must also have the ability to directly transmit data to a remote server in real-time by 4G.

Installation - Install the sensors and relevant power supply i.e., solar panels, at locations identified by the WMCA. This includes providing all relevant installation equipment e.g., cherry picker, monitor ties etc., and acquiring permissions to install the sensors and any traffic management permits which may be required. Decommissioning of the sensors at the end of the 5 year period will also be required if further funding hasn’t been sought to keep the network running.

Maintenance – Undertake all relevant maintenance requirements are per manufacturer guidance and in accordance with MCERT performance standards, as well as provide a remote sensor performance monitoring and alert system.

Sensor Calibration and Data QA/QC Requirements - Sensors must be compliant with the MCERTS performance standard for PM2.5 indicative ambient particulate monitors. The sensor supplier will be required to develop and share with the WMCA and University of Birmingham a QA/QC protocol which will ensure performance standards are met. Further to this, all sensors are required to have a minimum of 85% annual data capture (excluding periods of colocation).

Data Transmission and Data Platform Requirements - The sensor supplier will be responsible for setting up a data verification system and data transmission process which is compatible with WMCA data store and data platform, enabling data to move seamlessly from the sensors to the data store, and onto the data platform. This will need to be maintained for a minimum period of 5 years.

Monitoring and Evaluation - A monitoring and evaluation framework will need to be developed for this project to ensure consistency of analysis, including monthly data analysis reports.

Testun llawn y rhybydd

Hysbysiad gwybodaeth ymlaen llaw

Hysbysiad gwybodaeth ymlaen llaw yn unig yw hwn

Adran I: Endid contractio

I.1) Enw a chyfeiriad

West Midlands Combined Authority

16 Summer Lane

Birmingham

B19 3SD

UK

Person cyswllt: Victoria Taylor

Ffôn: +44 3453036760

E-bost: Victoria.Taylor@wmca.org.uk

NUTS: UK

Cyfeiriad(au) rhyngrwyd

Prif gyfeiriad: https://www.wmca.org.uk/

I.3) Cyfathrebu

Gellir cael gwybodaeth ychwanegol o'r cyfeiriad uchod


I.4) Y math o awdurdod contractio

Awdurdod rhanbarthol neu leol

I.5) Prif weithgaredd

Yr Amgylchedd

Adran II: Gwrthrych

II.1) Cwmpas y caffaeliad

II.1.1) Teitl

Air Quality Sensors

II.1.2) Prif god CPV

90711500

 

II.1.3) Y math o gontract

Gwasanaethau

II.1.4) Disgrifiad byr

Air pollution is a key challenge across the West Midlands, with the main pollutants of concern being NO2 and particulate matter (PM2.5 and PM10). To date, the focus on addressing air quality in the West Midlands (by both the West Midlands Combined Authority (WMCA) and the 7 constituent local authorities (https://www.wmca.org.uk/who-we-are/)) has been in lowering NO2 emissions; the predominant source of this is from road transport. The Environment Act (2021), which sets out the government’s framework for environmental legislation post-Brexit, has set new targets on addressing PM2.5 concentrations. These targets are for the annual mean PM2.5 levels to be of 10 μg/m3 or below by 2040, and for a population exposure reduction target of 35 % by 2040. Based on 2021 modelled baseline data by the University of Birmingham (UoB), 72 of the 192 wards within the WMCA would be in exceedance of this future target, which impacts 1.2 million people. Additionally, the least advantaged areas (highest IMD score) tend to have the worst air quality. Therefore, whilst tackling NO2 still remains a priority, there is a need to focus on tackling exposure to particulate matter pollution.

In March 2023, the WMCA was successful in securing a DEFRA grant to support collaborative work by the WMCA and local authorities on improving air quality across the region and build on partnership working with the UoB. The purpose of the grant is to improve the knowledge of the people who live and work in the West Midlands about air quality, and outline steps individuals can take to reduce their exposure to air pollution. To do this funding will be used to deliver a behaviour change programme and also, for the purpose of this procurement, to deliver the following, tailored to the needs of the 7 local authorities.

Installation of a low cost sensor network across the 7 constituent local authorities within the WMCA. This will focus on areas where there is modelled to be high population exposure to PM2.5. The sensors will have clear signage to ensure the public are aware of their purpose, and where further information can be found. These monitors will bring reliable consistent data, currently lacking, across the WMCA.

Create a public facing regional air quality platform. The sensor data will feed into a centralised dashboard for the public to see near real time air quality data, and other relevant air quality datasets. Datasets could include, but not limited to, local air quality modelling data, low pollution walking routes, traffic count data etc. The platform will be integrated into a wider website which will also be a hub of educational and campaign resources in relation to air pollution.

The WMCA requires an air quality sensor supplier to deliver the following:

Supply, install and maintain a network of low cost air quality sensors; and

Develop and maintain a data transmission system which enables data to be transmitted from the sensors to the WMCA data warehouse. A system will then upload data onto the WMCA air quality data platform. Both the data warehouse and data platform upload will be the responsibility of the WMCA but it is expected the supplier will work with WMCA to ensure the process from the sensor to the dashboard is compatible.

It is envisaged that the term of the contract will be for a duration of 5 years.

It should also be noted that this tender process is for the initial installation and deployment of a sensor network. It is expected that further funding will be sought in the future to further develop and expand the network with the potential for local stakeholders to also build sensors into the network.

II.1.5) Cyfanswm gwerth amcangyfrifedig

Gwerth heb gynnwys TAW: 550 000.00 GBP

II.1.6) Gwybodaeth am lotiau

Mae’r contract hwn wedi’i rannu’n lotiau: Na

II.2) Disgrifiad

II.2.2) Cod(au) CPV ychwanegol

35125100

II.2.3) Man cyflawni

Cod NUTS:

UK

II.2.4) Disgrifiad o’r caffaeliad

The WMCA requires an air quality sensor supplier to deliver the following:

Sensors - Minimum of 60 sensors to ensure spatial coverage across the 7 constituent local authorities. At a minimum, sensors must monitor PM2.5 at MCERT compliance standard, and it is preferable sensors can be reliably powered without the use of mains power. Sensors must also have the ability to directly transmit data to a remote server in real-time by 4G.

Installation - Install the sensors and relevant power supply i.e., solar panels, at locations identified by the WMCA. This includes providing all relevant installation equipment e.g., cherry picker, monitor ties etc., and acquiring permissions to install the sensors and any traffic management permits which may be required. Decommissioning of the sensors at the end of the 5 year period will also be required if further funding hasn’t been sought to keep the network running.

Maintenance – Undertake all relevant maintenance requirements are per manufacturer guidance and in accordance with MCERT performance standards, as well as provide a remote sensor performance monitoring and alert system.

Sensor Calibration and Data QA/QC Requirements - Sensors must be compliant with the MCERTS performance standard for PM2.5 indicative ambient particulate monitors. The sensor supplier will be required to develop and share with the WMCA and University of Birmingham a QA/QC protocol which will ensure performance standards are met. Further to this, all sensors are required to have a minimum of 85% annual data capture (excluding periods of colocation).

Data Transmission and Data Platform Requirements - The sensor supplier will be responsible for setting up a data verification system and data transmission process which is compatible with WMCA data store and data platform, enabling data to move seamlessly from the sensors to the data store, and onto the data platform. This will need to be maintained for a minimum period of 5 years.

Monitoring and Evaluation - A monitoring and evaluation framework will need to be developed for this project to ensure consistency of analysis, including monthly data analysis reports.

II.2.14) Gwybodaeth ychwanegol

Type of Procedure : Restricted

Time Limit for expressions of interest : 30 days

Technical and professional ability

Sensors must be MCERT Complaint for PM2.5

II.3) Dyddiad amcangyfrifedig ar gyfer cyhoeddi’r hysbysiad contract:

15/01/2024

Section IV: Gweithdrefn

IV.1) Disgrifiad

IV.1.8) Gwybodaeth am Gytundeb Caffael y Llywodraeth (GPA)

The procurement is covered by the Government Procurement Agreement: Ydy

Section VI: Gwybodaeth ategol

VI.3) Gwybodaeth ychwanegol

It is anticipated that once the sensor network has been established, we will be able to expand it as additional funding is sought.

A supplier engagement event will be held on 10th January at 13:00 – 14:00 where an overview of what we intend to procure will be provided as well as full overview of the procurement process. Please contact Victoria.Taylor@wmca.org.uk if you wish to attend.

VI.5) Dyddiad anfon yr hysbysiad hwn

12/12/2023

Codio

Categorïau nwyddau

ID Teitl Prif gategori
90711500 Monitro amgylcheddol heblaw ar gyfer adeiladu Asesu effeithiau amgylcheddol heblaw ar gyfer adeiladu
35125100 Synwyryddion System wyliadwriaeth

Lleoliadau Dosbarthu

ID Disgrifiad
100 DU - I gyd

Cyfyngiadau Rhanbarthol ar y Rhybuddion

Mae’r prynwr wedi cyfyngu’r rhybuddion ar gyfer yr hysbysiad hwn i gyflenwyr yn y rhanbarthau canlynol.

ID Disgrifiad
Nid oes cyfyngiadau ar y rhybuddion ar gyfer yr hysbysiad hwn.

Ynglŷn â'r prynwr

Prif gyswllt:
Victoria.Taylor@wmca.org.uk
Cyswllt gweinyddol:
N/a
Cyswllt technegol:
N/a
Cyswllt arall:
N/a

Gwybodaeth bellach

Dyddiad Manylion
Nid oes unrhyw wybodaeth bellach wedi'i lanlwytho.

0800 222 9004

Mae'r llinellau ar agor rhwng 8:30am a 5pm o ddydd Llun i ddydd Gwener.

Rydym yn croesawu galwadau'n Gymraeg.

We welcome calls in Welsh.